home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / generic / 07240dry.gen < prev    next >
Text File  |  1998-06-22  |  24KB  |  429 lines

  1.     SECTION 07240
  2.  
  3.     EXTERIOR INSULATION AND FINISH SYSTEM
  4. NOTE ** This section is based on the Outsulation MD System(R) manufactured by Dryvit(R) Systems, Inc., at the following address:
  5. NOTE **     One Energy Way
  6. NOTE **     P.O. Box 1014
  7. NOTE **     West Warwick, RI 02893
  8. NOTE **     Tel: (800) 556-7752 and (401) 822-4100
  9. NOTE **     Fax: (401) 822-1980
  10. NOTE ** 
  11. NOTE ** SECTION 07240 - EXTERIOR INSULATION AND FINISH SYSTEM, Copyright 1998, The Architect's Catalog, Inc.
  12.  
  13. NOTE ** Acceptable substrates for the Outsulation MD System are:
  14. NOTE **  -Unglazed brick
  15. NOTE **  -Cement plaster
  16. NOTE **  -Concrete
  17. NOTE **  -Concrete masonry
  18. NOTE **  -Exterior grade gypsum sheathing, ASTM C 79, with water-resistant or Type X core
  19. NOTE **  -Silicone-treated gypsum-core sheathing with inorganic fiberglass mat surface, ASTM C 1177
  20. NOTE **  -Exterior fiber reinforced cement or calcium silicate boards
  21.  
  22. PART 1    GENERAL
  23.  
  24. 1.1    SECTION INCLUDES
  25.  
  26.     A.    Exterior Insulation and Finish System (EIFS), Class PB, as defined by EIFS Industry Members Association (EIMA).
  27.  
  28. 1.2    RELATED SECTIONS
  29. NOTE ** Delete any sections below not relevant to this project; add others as required.
  30.  
  31.     A.    Section 03300 - Cast-In-Place Concrete.
  32.  
  33.     B.    Section 04810 - Unit Masonry Assemblies.
  34.  
  35.     C.    Section 05400 - Cold-Formed Metal Framing.
  36.  
  37.     D.    Section 06100 - Rough Carpentry.
  38.  
  39.     E.    Section 06115 - Sheathing.
  40.  
  41.     F.    Section 07210 - Building Insulation.
  42.  
  43.     G.    Section 07600 - Flashing and Sheet Metal.
  44.  
  45.     H.    Section 07900 - Joint Sealers.
  46.  
  47. 1.3    REFERENCES
  48.  
  49.     A.    ASTM B 117 - Operating Salt Spray (Fog) Apparatus.
  50.  
  51.     B.    ASTM C 1063 - Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster.
  52.  
  53.     C.    ASTM D 968 - Abrasion Resistance of Organic Coatings by Falling Abrasive.
  54.  
  55.     D.    ASTM D 1784 - Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds.
  56.  
  57.     E.    ASTM D 2247 - Testing Water Resistance of Coatings in 100 Percent Relative Humidity.
  58.  
  59.     F.    ASTM E 84 - Surface Burning Characteristics of Building Materials.
  60.  
  61.     G.    ASTM E 96 - Water Vapor Transmission of Materials.
  62.  
  63.     H.    ASTM E 108 - Fire Tests of Roof Coverings.
  64.  
  65.     I.    ASTM E 283 - Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.
  66.  
  67.     J.    ASTM E 330 - Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
  68.  
  69.     K.    ASTM E 331 - Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
  70.  
  71.     L.    ASTM G 23 - Operating Light-Exposure Apparatus (Carbon-Arc Type) With and Without Water for Exposure of Nonmetallic Materials.
  72.  
  73.     M.    BOCA National Building Code Radiant Heat Exposure Test of Exterior Wall Assemblies.
  74.  
  75.     N.    EIMA Standard 101.86.
  76.  
  77.     O.    Mil Standard 810B.
  78.  
  79.     P.    UBC 26-9.
  80.  
  81. 1.4    SYSTEM DESCRIPTION
  82.  
  83.     A.    Design Requirements:
  84.         1.    Deflection of Substrate System:  Not exceeding 1/240 times the span.
  85.         2.    Substrate Flatness:  Within 1/4 inch (6.4 mm) in a 4 foot (1.2 m) radius.
  86.         3.    Slope of Inclined Surfaces:  Not less than 6:12, length not exceeding 12 inches (305 mm).
  87.         4.    Zones requiring Impact Resistance Classification higher than Level 1 (as defined by EIMA Standard 101.86):  Detailed and described in Contract Documents.
  88.  
  89.     B.    Performance Requirements:
  90.         1.    EIFS tested for durability as follows:
  91.             a.    Abrasion Resistance:  ASTM D 968; no deleterious effects after 132 gallons (500 L).
  92.             b.    Absorption, Freeze-Thaw:  60 cycles, soak at 68 degrees F (20 degrees C) 4 days, then 14 degrees F (-10 degrees C) 2 hours, then 68 degrees F (20 degrees C) 2 hours; no checking, cracking, or splitting.
  93.             c.    Accelerated Weathering:  ASTM G 23 (Federal Test Standard 141A, Method 6151); 2,000 hours; no deterioration.
  94.             d.    Mildew Resistance:  Mil Standard 810B; passes.
  95.             e.    Moisture Resistance:  ASTM D 2247 (Federal Test Standard 141A, Method 6201); 14 days, no deleterious effects.
  96.             f.    Salt Spray Resistance:  ASTM B 117 (Federal Test Standard 141A, Method 6061); 5 percent concentration, 300 hours, no deleterious effects.
  97.             g.    Air Leakage: ASTM E 283; less than 0.001 CFM/sq. ft. (0.301 L/min/sq. m), classified as Type III air barrier by National Research Council of Canada.
  98.             h.    Water Penetration:  ASTM E 331; no water penetration to innermost surface of test specimen.
  99.             i.    Moisture Drainage Efficiency:  Modified ASTM E 331; 95 percent efficiency.
  100.             j.    Water Vapor Transmission:  ASTM E 96, Procedure B, Standard lamina; 14 grams/hour-sq. ft. (10 g/hr-sq. m).
  101.         2.    EIFS tested for structural performance as follows:
  102. NOTE ** Include structural performances below required for project; consult manufacturer's product data for selection assistance.
  103.             a.    Tensile Bond Strength, Backstop to Exterior Grade Gypsum Sheathing:  9.1 psi (67.7 kPa), sheathing facer failure.
  104.             b.    Tensile Bond Strength, Backstop to Fiberglass Mat-Surfaced Gypsum Sheathing:  28.8 psi (198.6 kPa), sheathing facer failure.
  105.             c.    Tensile Bond Strength, Primus to Backstop:  12.6 psi (86.9 kPa).
  106.             d.    Tensile Bond Strength, Genesis to Backstop:  15.1 psi (104 kPa), sheathing facing failure.
  107.             e.    Full-Scale Structural Tests:  ASTM E 330; minimum failure load under positive or negative load of 90 psf (4.3 kPa) unless otherwise specified; substrate failure.
  108. NOTE ** Insert required impact range below; consult manufacturer's product data for selection assistance.
  109.             f.    Impact Resistance:  EIMA Standard 101.86; ______ inch-pounds (_______ J).
  110.         3.    EIFS tested for fire performance as follows:
  111.             a.    Flame Spread/Smoke Developed, EPS Insulation Board:  ASTM E 84; 25/450.
  112.             b.    Flame Spread/Smoke Developed, Adhesives and Coatings:  ASTM E 84; 20/10.
  113.             c.    Full Scale Fire Test:  ASTM E 108 (Modified); passed.
  114.             d.    Intermediate Scale Multi-Story Test (ISMA):  UBC 26-9; passed.
  115.             e.    Ignitability Characteristics:  BOCA National Building Code Radiant Heat Exposure Test of Exterior Wall Assemblies; passed.
  116.  
  117. 1.5    SUBMITTALS
  118.  
  119.     A.    Submit under provisions of Section 01300.
  120.  
  121.     B.    Product Data:  Manufacturer's descriptive literature for each specified product.
  122.  
  123.     C.    Quality Assurance Submittals:
  124.         1.    Certificates:  Contractor's certification that:
  125.             a.    Products of this Section, as provided, meet or exceed specified requirements.
  126.             b.    Manufacturers of products of this section meet specified qualifications.
  127.             c.    Applicator of products of this section meets specified qualifications.
  128.         2.    Manufacturer's instructions:
  129.             a.    Printed installation instructions for each specified product.
  130.             b.    Manufacturer's Safety Data Sheets (M.S.D.S.) for each specified product.
  131.  
  132.     D.    Closeout Submittals:  Warranty documents, issued and executed by manufacturer of EIFS materials.
  133.  
  134. 1.6    QUALITY ASSURANCE
  135.  
  136.     A.    Qualifications:
  137.         1.    Manufacturer of EIFS Materials:  Minimum five (5) years documented experience producing EIFS materials specified in this section, sponsor of applicator certification program, sponsor of certification and quality assurance program for manufacturers of materials for EIFS installations not produced by EIFS materials manufacturer, and certified by ISO 9001.
  138. NOTE ** The Trained Contractor Certificate required by the following subparagraph indicates that certain employees of the company have been instructed in the proper application of Dryvit products and have received copies of Dryvit's Application Instructions and Specifications.  The Trained Contractor Program is not an apprenticeship or endorsement.  Each trained contractor is an independent company experienced in the trade and bears responsibility for its own workmanship.  Dryvit assumes no liability for the workmanship of a trained contractor.
  139.         2.    Contractor:  Knowledgeable in the proper installation of EIFS materials specified in this section, experienced and competent in the installation of EIFS, and possessing current Trained Contractor Certificate issued by the EIFS manufacturer.
  140.         3.    Manufacturer of Insulation Materials:  Manufacturer having insulating board product listed as meeting EIFS materials manufacturer's insulation board specification, and as participant in EIFS manufacturer's third-party certification and quality assurance program.
  141.         4.    Panel Fabricator:  Experienced and competent in the fabrication of architectural wall panels.
  142.         5.    Installer:  Experienced and competent in the installation of architectural wall panels; the Panel Fabricator, approved by the Panel Fabricator, or under direct supervision of the Panel Fabricator.
  143.  
  144.     B.    Regulatory Requirements:
  145.         1.    Separate expanded polystyrene from building interior with 15-minute minimum thermal barrier.
  146.         2.    Expanded polystyrene use and maximum thickness shall be in accordance with applicable building codes.
  147.  
  148.     C.    Mock-ups:
  149.         1.    Construct mock-up of size indicated on drawings; locate on project site as directed by Architect.
  150.         2.    Prepare substrate and apply finish as specified in this section.
  151.         3.    Maintain mock-up at project site until Architect directs its removal.
  152.  
  153. 1.7    DELIVERY, STORAGE, AND HANDLING
  154.  
  155.     A.    Packing, Shipping, Handling and Unloading:  Deliver products to project site in manufacturer's labeled and sealed packaging.
  156.  
  157.     B.    Acceptance at Site:  Accept only products in sealed, unopened manufacturer's packaging with labels intact.
  158.  
  159.     C.    Storage and Protection:
  160.         1.    Store products in manufacturer's unopened packaging until installation.
  161.         2.    Maintain dry storage area at minimum 45 degrees F (7 degrees C) for products until removal for installation.
  162.         3.    Protect product from weather and direct sunlight.
  163.  
  164. 1.8    PROJECT/SITE CONDITIONS
  165.  
  166.     A.    Environmental Requirements:
  167.         1.    Applying products of this section during periods of inclement weather is prohibited, except where surfaces to receive products are protected from weather during application and until applied products are cured.
  168.         2.    Apply products of this section only above minimum ambient temperature of 45 degrees F (7 degrees C) and when ambient temperature will remain minimum 45 degrees F (7 degrees C) for following 24 hour period.
  169. NOTE ** Delete the following article if no warranties are required, or if work is covered under the terms of a general project warranty specified elsewhere.  You may edit the article to obtain a warranty from the Contractor only, or to suit other project-specific criteria.  Dryvit assumes no responsibility for workmanship associated with the installation or application of materials, and makes no other warranties, expressed or implied.  Full details are available from Dryvit Systems, Inc.
  170.  
  171. 1.9    WARRANTY
  172.  
  173.     A.    Manufacturer's Warranty:  Supply EIFS materials manufacturer's 7-year warranty against defects in materials only.  Manufacturer shall have no liability for application of materials.
  174.  
  175.     B.    The Installer shall separately warrant EIFS against failure due to workmanship for a period of 5 years from the date of Substantial Completion.
  176.  
  177.  
  178. PART 2    PRODUCTS
  179.  
  180. 2.1    MANUFACTURERS
  181.  
  182.     A.    Acceptable Manufacturer:  Dryvit Systems, Inc.; One Energy Way, P.O. Box 1014, West Warwick RI 02893; ASD. Tel: (800) 556-7752 and (401) 822-4100; Fax: (401) 822-1980.
  183. NOTE ** Delete one of the two paragraphs below; coordinate with Division 1 requirements.
  184.  
  185.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.
  186.  
  187.     C.    Substitutions:  Not permitted.
  188. NOTE ** Delete paragraph below if substitutions not permitted.
  189.  
  190.     D.    Supply all products specified in this section from a single manufacturer, or that manufacturer's authorized distributor.
  191.  
  192. 2.2    MATERIALS
  193.  
  194.     A.    Air/Weather Barrier:
  195.         1.    Dryvit Backstop:  100 percent acrylic, field-mixed.
  196.         2.    Dryvit Grid Tape:  Open-weave fiberglass mesh tape, pressure sensitive adhesive.
  197.         3.    Dryvit Flashing Tape:  High-density polyethylene backed tape with rubberized asphalt adhesive.
  198.         4.    Dryvit Flashing Tape Surface Conditioner:  Water-based surface conditioner and adhesion promoter for Flashing Tape.
  199. NOTE ** Select correct adhesive/base coat from the following two paragraphs;  consult manufacturer's product data for selection assistance.
  200.  
  201.     B.    Adhesive/Base Coat:  Dryvit Genesis(R) fiber-reinforced, acrylic modified; field-mixed with Portland cement in 1:1 ratio.
  202.  
  203.     C.    Adhesive/Base Coat:  Dryvit Primus(R) acrylic polymer-based; field-mixed with Portland cement in 1:1 ratio.
  204.  
  205.     D.    OMD Insulation Board:  Expanded polystyrene meeting EIFS manufacturer's specification for insulation board.
  206.         1.    Thickness:  As indicated on drawings, 2 inches (50 mm) minimum.
  207.         2.    Back Side:  1/4 inch by 1 inch (6 x 25 mm) vertical grooves at 12 inches (305 mm) on center.
  208.  
  209.     E.    OMD Insulation Board Closure Blocks:  Expanded polystyrene meeting EIFS manufacturer's specification for insulation board.
  210.         1.    Height:  6 inches (150 mm) minimum.
  211.  
  212.     F.    Starter Strip:  Expanded polystyrene meeting EIFS manufacturer's specification for insulation board.
  213.         1.    Height:  6 inches (150 mm) minimum
  214.         2.    Configuration:  To receive OMD Insulation Board.
  215.  
  216.     G.    Vent Assembly:  Formed aggregate matrix material encased in piece of insulation board which provides drainage capability.
  217.  
  218.     H.    Track:  ASTM D 1784 and C 1063; "J"-shaped.
  219.  
  220.     I.    Vent Track:  ASTM D 1784 and C 1063; "J"-shaped with drainage slot.
  221. NOTE ** Delete mesh types not required in the following paragraphs; meshes are classified by impact resistance and specified by weight; consult manufacturer's product data for selection assistance.
  222.  
  223.     J.    Standard Weight Reinforcing Mesh:
  224.         1.    Acceptable Product:  Dryvit Standard(tm) Mesh.
  225.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 4.3 ounces per square yard (146 g/sq m).
  226.  
  227.     K.    Medium Weight Reinforcing Mesh:
  228.         1.    Acceptable Product:  Dryvit Standard Plus(tm) Mesh.
  229.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 6.0 ounces per square yard (203 g/sq. m).
  230.  
  231.     L.    Intermediate Weight Reinforcing Mesh:
  232.         1.    Acceptable Product:  Dryvit Intermediate(R) Mesh.
  233.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 12.0 ounces per square yard (407 g/sq. m).
  234.  
  235.     M.    Heavy Weight Reinforcing Mesh:
  236.         1.    Acceptable Product:  Dryvit Panzer(R) 15 Mesh.
  237.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 15.0 ounces per square yard (509 g/sq. m).
  238.  
  239.     N.    Extra Heavy Weight Reinforcing Mesh:
  240.         1.    Acceptable Product:  Dryvit Panzer(R) 20 Mesh.
  241.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 20.5 ounces per square yard (695 g/sq. m).
  242.  
  243.     O.    Detail(R) Reinforcing Mesh:
  244.         1.    Acceptable Product:  Dryvit Detail Short Roll.
  245.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 4.3 ounces per square yard (146 g/sq. m).
  246.  
  247.     P.    Corner Reinforcing Mesh:
  248.         1.    Acceptable Product:  Dryvit Corner Mesh.
  249.         2.    Product Description:  Glass-fiber fabric, balanced and treated for compatibility with other EIFS materials; weight 7.2 ounces per square yard (244 g/sq. m).
  250. NOTE ** Delete finishes not required in the following paragraphs; consult manufacturer's product data for selection assistance.
  251.  
  252.     Q.    Finish:
  253.         1.    Type:  Standard DPR (Dirt-Pickup Resistant) Finish.
  254. NOTE ** Insert selected texture in following paragraph; select from list below:
  255. NOTE ** Dryvit Quarzputz(R); Coarse
  256. NOTE ** Dryvit Sandblast(R); Medium
  257. NOTE ** Dryvit Freestyle(R); Fine
  258. NOTE ** Dryvit Sandpebble(R); Pebble Stucco
  259. NOTE ** Dryvit Sandpebble Fine(tm); Fine Pebble
  260. NOTE ** 
  261. NOTE ** Consult manufacturer's product data for selection assistance.
  262.         2.    Texture:  Dryvit ___________________.
  263. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  264.         3.    Color:  Selected from full range of manufacturer's standard colors.
  265.         4.    Color:  _________________.
  266.         5.    Color:  Specified in SCHEDULES Article of this Section.
  267.  
  268.     R.    Finish:
  269.         1.    Type:  Elastomeric DPR (Dirt-Pickup Resistant) Finish.
  270. NOTE ** Insert selected texture in following paragraph; select from list below:
  271. NOTE ** Dryvit Weatherlastic(tm) Quarzputz
  272. NOTE ** Dryvit Weatherlastic Sandpebble
  273. NOTE ** Dryvit Weatherlastic Sandpebble Fine
  274. NOTE ** Dryvit Weatherlastic Adobe(tm)
  275. NOTE ** 
  276. NOTE ** Consult manufacturer's product data for selection assistance.
  277.         2.    Texture:  Dryvit Weatherlastic ___________________.
  278. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  279.         3.    Color:  Selected from full range of manufacturer's standard colors.
  280.         4.    Color:  _________________.
  281.         5.    Color:  Specified in SCHEDULES Article of this Section.
  282.  
  283.     S.    Finish:
  284.         1.    Type:  Medallion Series PMR(tm) (Proven Mildew Resistance) Finish.
  285. NOTE ** Insert selected texture in following paragraph; select from list below:
  286. NOTE ** Dryvit Quarzputz
  287. NOTE ** Dryvit Sandblast
  288. NOTE ** Dryvit Freestyle
  289. NOTE ** Dryvit Sandpebble
  290. NOTE ** Dryvit Sandpebble Fine
  291. NOTE ** 
  292. NOTE ** Consult manufacturer's product data for selection assistance.
  293.         2.    Texture:  Dryvit  ___________________.
  294. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  295.         3.    Color:  Selected from full range of manufacturer's standard colors.
  296.         4.    Color:  _________________.
  297.         5.    Color:  Specified in SCHEDULES Article of this Section.
  298.  
  299.     T.    Finish:
  300.         1.    Type:  Specialty Finish.
  301. NOTE ** Insert selected texture in following paragraph; select from list below:
  302. NOTE ** Ameristone(tm) multi-colored quartz aggregate
  303. NOTE ** Stone Mist(R) ceramically-colored quartz aggregate
  304. NOTE ** 
  305. NOTE ** Consult manufacturer's product data for selection assistance.
  306.         2.    Texture:  _________________.
  307. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  308.         3.    Color:  Selected from full range of manufacturer's standard colors.
  309.         4.    Color:  _________________.
  310.         5.    Color:  Specified in SCHEDULES Article of this Section.
  311.  
  312.     U.    Finish:
  313.         1.    Type:  Specialty Finish.
  314. NOTE ** Insert selected texture in following paragraph; select from list below:
  315. NOTE ** Ultra-Tex(R) Polymer Finish
  316. NOTE ** Ultra-Tex(R) Cementitious Finish
  317. NOTE ** 
  318. NOTE ** Consult manufacturer's product data for selection assistance.  Ultra-Tex Cementitious Finish requires an annual application of Ultra-Tex Sealer.
  319.         2.    Texture:  ___________________.
  320. NOTE ** Determine method of color selection; retain one of following three paragraphs.  Coordinate selection method with requirements for Samples in SUBMITTALS Article of Part 1.  If more than one color required, retain third paragraph below and coordinate with SCHEDULES Article of Part 3.
  321.         3.    Color:  Selected from full range of manufacturer's standard colors.
  322.         4.    Color:  _________________.
  323.         5.    Color:  Specified in SCHEDULES Article of this Section.
  324. NOTE ** Select one or more of the following paragraphs if required; consult manufacturer's product data for selection assistance.
  325.         6.    Coating:  Dryvit Demandit(R).
  326.         7.    Coating:  Dryvit Weatherlastic Smooth(tm).
  327.         8.    Coating:  Dryvit Revyvit(R).
  328.         9.    Primer:  Dryvit Color Prime(tm).
  329.         10.    Primer:  Dryvit Prymit(R).
  330.         11.    Sealer:  Dryvit Ultra-Tex Sealer.
  331.         12.    Sealer:  Dryvit SealClear(tm).
  332. NOTE ** Delete one of the following two paragraphs; consult manufacturer's product data for selection assistance.
  333.  
  334.     V.    Joint Sealer Primer:  Dryvit Demandit.
  335.  
  336.     W.    Joint Sealer Primer:  Dryvit Color Prime.
  337.  
  338.     X.    Joint Sealers:  Specified in Section 07900.
  339.  
  340. 2.3    MIXES
  341.  
  342.     A.    Prepare materials requiring field-mixing for application in accordance with manufacturer's printed installation instructions.
  343.  
  344.  
  345. PART 3    EXECUTION
  346.  
  347. 3.1    EXAMINATION
  348.  
  349.     A.    Verification of Conditions:
  350.         1.    Substrates to receive EIFS are listed in manufacturer's printed installation instructions as acceptable.
  351. NOTE ** Ensure that expansion joints are located and detailed on drawings; consult manufacturer's product data for recommended types and spacings.
  352.         2.    Expansion joints are located and sized as indicated on drawings.
  353.         3.    Products indicated to be installed in surfaces to receive EIFS are installed in correct locations.
  354.  
  355.     B.    Installer's Examination:
  356.         1.    Examine conditions under which construction activities of this Section are to be performed; submit written notification if such conditions are unacceptable.
  357.         2.    Transmit two copies of Installer's report to Architect within 24 hours of receipt.
  358.         3.    Beginning construction activities of this section before unacceptable conditions have been corrected is prohibited.
  359.         4.    Beginning construction activities of this section indicates Installer's acceptance of conditions.
  360.  
  361. 3.2    PREPARATION
  362.  
  363.     A.    Protection:  Mask surfaces of adjacent materials to prevent damage to finishes.
  364.  
  365.     B.    Surface Preparation:  Prepare surfaces to receive EIFS in accordance with manufacturer's printed installation instructions.
  366.  
  367. 3.3    APPLICATION
  368.  
  369.     A.    Air/Weather Barriers:  Apply in accordance with manufacturer's printed installation instructions for project substrate types.
  370.  
  371.     B.    Adhesive/Base Coats:  Apply types specified in manufacturer's printed installation instructions for project substrate types to prepared surfaces.
  372.  
  373.     C.    OMD Insulation Board:  Apply indicated thicknesses, and to form indicated profiles; maintain joint spacing specified in manufacturer's printed installation instructions.
  374.  
  375.     D.    Base Coats:  Apply types and number of coats specified in manufacturer's printed installation instructions sufficient to fully embed mesh.
  376.  
  377.     E.    Reinforcing Mesh:  Apply types specified to building areas indicated on drawings, and as recommended in manufacturer's printed installation instructions.
  378.  
  379.     F.    Finishes:  Apply specified finishes and colors in accordance with manufacturer's printed installation instructions.
  380.  
  381.     G.    Sealer:  Apply specified sealers to indicated finishes in accordance with manufacturer's printed installation instructions.
  382.  
  383.     H.    Joint Sealer Primer:  Apply to finish surfaces to receive joint sealers in accordance with manufacturer's printed installation instructions.
  384.  
  385.     I.    Installation of joint sealers is specified in Section 07900.
  386.  
  387.     J.    Installation of flashing and sheet metal is specified in Section 07600.
  388.  
  389. 3.4    PROTECTION
  390.  
  391.     A.    Maintain protection of unsealed edges of EIFS finishes from weather until installation of flashings and joint sealers.
  392.  
  393.     B.    Protect EIFS finishes from damage by subsequent construction activities until Substantial Completion.
  394.  
  395.     C.    Repair EIFS finishes damaged by subsequent construction activities in accordance with manufacturer's printed installation instructions; replace EIFS finish to extent of nearest adjacent termination each way at areas where repair to finish is judged unacceptable.
  396.  
  397.     D.    Architect will be sole judge of acceptability of repaired finishes.
  398. NOTE ** Complete the following suggested schedule if more than one finish or color is required for project; delete Article if not required.
  399.  
  400. 3.5    SCHEDULES
  401.  
  402.     A.    Location:  _______________.
  403.         1.    Texture:  ____________.
  404.         2.    Color:  ______________.
  405.  
  406.     B.    Location:  _______________.
  407.         1.    Texture:  ____________.
  408.         2.    Color:  ______________.
  409.  
  410.     C.    Location:  _______________.
  411.         1.    Texture:  ____________.
  412.         2.    Color:  ______________.
  413.  
  414.  
  415.     END OF SECTION
  416. ??
  417.  
  418.  
  419.  
  420.  
  421.  
  422.  
  423.  
  424.  
  425.  
  426.     07240-1